Flame Spread Rating For Carpet
When paints are applied to substrate materials that have been tested and classified interior paints and coatings have been found to have no effect on the flame spread index or smoke density index of rated materials.
Flame spread rating for carpet. From these observations a flame spread rating can be calculated. Materials tested in accordance with sec tion 803 1 2. Fsi is the measurement for the speed at which flames progress across the interior surface of a building while sdi measures the amount of smoke a sample emits as it burns. This test measures the flame spread of flooring systems like carpet in corridors and exits.
Explore the look book now. For example if the flame travels 19 1 2 feet in less than 5 1 2 minutes the time required for flame to spread on 19 1 2 feet of red oak the rating is 100 times 5 1 2 divided by the time minutes in which flame spreads 19 1 2 feet on the sample. General installation guidelines commercial. Commonly referred to as the pill test it is used to determine whether a carpet will spread a newly started fire.
Infinity six foot. Xpressstep carpet tile adhesive sds. Through the e 84 test both the flame spread index fsi and smoke developed index sdi are reported for a given sample. It was never designed to be a floor covering test and was only adopted for floors as an interim test method.
Cross band signature installation against the grain collection only. Boxweave signature installation against the grain collection only. Radiant heat is applied by means of a gas fueled panel inclined at a 30ยบ angle over horizontally installed flooring mounted on concrete just like real carpeted corridors. The e 84 tunnel test has been retired many years ago as a floor covering flammability test.
What do the flame spread ratings mean. To can ulc s102 2 with maximum flame spread rating of 300 and maximum smoke developed rating of 450. However it continues to be the most widely used surface flame spread test for wall and ceiling finishes. Shaw hospitality group is dedicated to delivering new and innovative carpet and flooring designs to the hospitality industry worldwide.
04 of the procedures developed for assessing flame spread and smoke developed ratings of floor coverings the most common methods currently in use are. Flame spread index 76 200. The test measures the response or flame resistance to. Shaw sports turf has demonstrated industry leadership in both quality and.
Carpet used on vertical surfaces other than carpet base shall meet code rating requirements for wall coverings. This test is designed to simulate thermal radiation levels from an adjacent. Flame spread index 26 75. Xpressstep carpet tile adhesive installation.